nVent Nuheat Logo, nuheat.com
 

Cable & Membrane Overview

Home, nuheat.com
STRATA HEAT Mat.jpg

Product Name

STRATA_HEAT Cable & Membrane


Indoor Use Only

YES


Online Estimator Tool

yes, click here

120V Sizes - designed at 13 w/sqft

15, 20, 25, 30, 40, 50, 60, 70, 80, 90, 110, 120 (sqft)

 
Cable With Spacing strips Design Guide
Cable & membrane Design Guide
 

240V Sizes - designed at 13 w/sqft

25, 30, 40, 50, 60, 70, 80, 90, 100, 125, 150, 175, 200, 225, 250 (sqft)

 
Cable with Spacing strips Design Guide
cable & membrane design guide
 

Max Heat Output

16 watts/sqft


Cable Spacing w/guides

10 w/sqft - 4”

13 w/sqft - 4”


Cable Spacing w/membrane

10 w/sqft - 4 peg

13 w/sqft - 3 peg

16 w/sqft - 3/2/3 alternate peg


Cable Guides Included

YES


Self-Leveling Concrete Using Cable Guides

Thin-set or self-leveling


Cable Thickness

3/16”


Zero EMF

0.5 mG


Waterproof Cable

YES, but only 120V - click here for details

Halfway Marker on Cable

YES


Cable Repair Kit Available

YES


Cable Must be Turned After 10’

No; Unlimited Straight Runs


Cold Lead Length

10’


Cable Splice and Sensor Probe Fits without Cutting Membrane

YES


Membrane Rolls Sizes

161 sqft


Membrane Sheet Sizes

8.6 sqft - 2’6”x3’3”


Membrane Thickness

.25” - 6.4mm


Adjusted Floor Height

Cable w/guides - 1/4”

Cable w/membrane - 1/2”


NO

Waterproof Membrane


Self-Leveling Concrete over Membrane

Yes, approved levelers here

Yes, see page 23

Modified Thinset Approved Above and Below Membrane


Minimum Tile Size Over Membrane

No minimum with use of self-leveler; 3.5”x3.5” over thin-set


YES

UL Approved under Laminate


YES

UL Approved under Luxury Vinyl Tile


YES

UL Approved under Engineered Hardwood


Membrane - Robinson Floor Test - OSB/Plywood w/19.2” O.C Joists - 12”x12” Porcelain

1/5 - Residential


Membrane - Robinson Floor Test - Concrete - 12”x12” Porcelain

2/5 - Light


Membrane Approved for Sound Reduction

NO


Is the Membrane a Thermal Break?

NO


Cable Warranted in Other Membranes

YES, 5 Years


Membrane Warranted with Other Cable

YES, 5 Years


Warranty in Effect After Repairs

NO

Cable & Membrane Warranty

5 Year Warranty - cable & membrane used separately
25 Year Warranty - all products here used in conjunction
10 Year warranty - all products here used in conjunction
lifetime Warranty - all products here used in conjunction

helpful Videos

STRATA_HEAT Radiant Floor Heating System Components and Demo

STRATA_HEAT™ Wire Installation

STRATA_HEAT™ Mat Installation

LATICRETE® STRATA_MAT™

STRATA_HEAT™ THERMAL PACK

Laticrete Strata Heat Product Webinar


Downloads

strata_heat Brochure
strata_heat spliceless wire data sheet
STRAT_HEAT cable and membrane installation guide
STRAT_MAT Data sheet
STRATA_HEAT FAQ

Back to Cable & Membrane Review